Europe USA Warehouse Hybrid Solar Inverter 24/48V 3000/5000w Onduleur With MPPT Charge Controller Inversor

Europe USA Warehouse Hybrid Solar Inverter 24/48V 3000/5000w Onduleur With MPPT Charge Controller Inversor

Additional information

Output Frequency

50Hz/ 60Hz

Size

430mm*338mm*126mm

Inverter Efficiency

97%

Weight

13KG

Communication

RS485/WiFi (optional)/GPRS (optional)

Protection

Short Circuit Protection

Product Information

TTN Hybrid Solar Inverter

 

An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity altogether.

 
The Grid-interactive inverter consists of several hardware elements. The Grid-interactive Hybrid Solar Power inverter controls and monitors the connection of the electricity from the power plants. In addition, it also controls the disconnection of excess power from the plants. It ensures the dispatch of power at the peak time based on demand.
TTN-HF4850S80/HF4835U80-145
 
All-in-one solar charge inverter
 

· Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sinewave. · Two output modes: mains bypass and inverter output; uninterrupted power supply. · Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging. · Advanced MPPT technology with an efficiency of 99.9%. ·With the charging requirement (voltage, current, mode) settings, and suitable for various types of energy storage batteries. · ON/OFF rocker switch for AC output control. · Power saving mode available to reduce no-load loss. ·Intelligent variable speed fan to efficiently dissipate heat and extend system life. · Lithium battery activation design, allowing access of lead-acid batteries and lithium batteries. · 360 ° all-round protection with a number of protection functions. Such as overload, short circuit and overcurrent. · Supply of a variety of user-friendly communication modules, such as RS485(GPRS, Wi-Fi), CAN, USB etc., and suitable for computer, mobile phones, Internet monitoring as well as remote operations. · Available for 6 units parallel connection. · Available for split phase connection.

Models
HF4850S80-145
HF4835U80-145
AC mode
Rated input voltage
220/230Vac
110/120Vac
Input voltage range
(170Vac~280Vac)±2% / (90Vac-280Vac)±2%
(90Vac~140Vac)±2%
Frequency
50Hz/60Hz(Auto detection)
Parallelable/Split Phase units
Max. parallelable unit: 6pcs
Frequency Range
47±0.3Hz~55±0.3Hz(50Hz)/57±0.3Hz~65±0.3Hz(60Hz)
Overload/short circuit protection
Circuit breaker
Efficiency
>95%
Conversion time(bypass and inverter)
10ms(typical)
AC reverse protection
Available
Maximum bypass overload current
40A
Inverter mode
Output voltage waveform
Pure sine wave
Rated output power(VA)
5000
3500
Rated output power (W)
5000
3500
Power factor
1
Rated output voltage(Vac)
230Vac
120Vac
Output voltage error
±5%
Output frequency range (Hz)
50Hz±0.3Hz/60Hz±0.3Hz
Maximum Efficiency
>92%
>91%
Overload protection
(102%<125%)±10%: report error and turn off the
output after 5 minutes; (125%<150%)±10%: report
error and turnoff the output after 10 seconds; Load >150%

<125%)±10%: report error and turn off the

±10%: report error and tun off the output after 5 seconds;
(102%<110%)±10%: report error and turn off the
output after 5 minutes; (110%<125%)±10%: report
error and turn off the output after 10 seconds;(Load >125%

<110%)±10%: report error and turn off the

±10%): report error and turn off the output after5 seconds;
Peak power
10000VA
6000VA
Loaded motor capability
4HP
2HP
Output short circuit protection
Circuit breaker
Bypass breaker specifications
40A
Rated battery input voltage
48V(Minimum starting voltage 44V)
Battery voltage range
Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery…settable on LCD screen)
Power saving mode
Load ≤50W
AC charging
Battery type
Lead acid or lithium battery
Maximum charge current
60A
40A
Charge curent error
±5Adc
Charge voltage range
40Vdc~58Vdc
40Vdc~60Vdc
Short circuit protection
Circuit breakerand blown fuse
Circuit breaker specifications
40A
Overcharge protection
Alarm and turn off charging after 1 minute
PV charging
Maximum PV open circuit voltage
145Vdc
PV operating voltage range
60-145Vdc
MPPT voltage range
60-115Vdc
Battery voltage range
40-60Vdc
Maximum output power
4200W
PV charging current range (can be set)
0-80A
Charging short circuit protection
Blown fuse
Wiring protection
Certified specifications
Reverse polarity protection
Certification
CE(EN62040-1)
EMC certification level
EN62040-2, C2
Operating temperature range
-15℃ to 55℃
Storage temperature range
-25℃~60℃
Humidity range
5% to 95%(Conformal coating protection)
Noise
≤60dB
Heat dissipation
Forced air cooling, variable speed of fan
Communication interface
USB/RS485(WiFi/GPRS)/Dry node control
Size(L*W*D)
426*322*124mm
Weight(kg)
10.8
Product Details

Enquiry more about: Europe USA Warehouse Hybrid Solar Inverter 24/48V 3000/5000w Onduleur With MPPT Charge Controller Inversor