Output Frequency | 50Hz/ 60Hz |
---|---|
Size | 430mm*338mm*126mm |
Inverter Efficiency | 97% |
Weight | 13KG |
Communication | RS485/WiFi (optional)/GPRS (optional) |
Protection | Short Circuit Protection |
An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity altogether.
· Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sinewave. · Two output modes: mains bypass and inverter output; uninterrupted power supply. · Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging. · Advanced MPPT technology with an efficiency of 99.9%. ·With the charging requirement (voltage, current, mode) settings, and suitable for various types of energy storage batteries. · ON/OFF rocker switch for AC output control. · Power saving mode available to reduce no-load loss. ·Intelligent variable speed fan to efficiently dissipate heat and extend system life. · Lithium battery activation design, allowing access of lead-acid batteries and lithium batteries. · 360 ° all-round protection with a number of protection functions. Such as overload, short circuit and overcurrent. · Supply of a variety of user-friendly communication modules, such as RS485(GPRS, Wi-Fi), CAN, USB etc., and suitable for computer, mobile phones, Internet monitoring as well as remote operations. · Available for 6 units parallel connection. · Available for split phase connection.
Models
|
HF4850S80-145
|
HF4835U80-145
|
AC mode
|
||
Rated input voltage
|
220/230Vac
|
110/120Vac
|
Input voltage range
|
(170Vac~280Vac)±2% / (90Vac-280Vac)±2%
|
(90Vac~140Vac)±2%
|
Frequency
|
50Hz/60Hz(Auto detection)
|
|
Parallelable/Split Phase units
|
Max. parallelable unit: 6pcs
|
|
Frequency Range
|
47±0.3Hz~55±0.3Hz(50Hz)/57±0.3Hz~65±0.3Hz(60Hz)
|
|
Overload/short circuit protection
|
Circuit breaker
|
|
Efficiency
|
>95%
|
|
Conversion time(bypass and inverter)
|
10ms(typical)
|
|
AC reverse protection
|
Available
|
|
Maximum bypass overload current
|
40A
|
|
Inverter mode
|
||
Output voltage waveform
|
Pure sine wave
|
|
Rated output power(VA)
|
5000
|
3500
|
Rated output power (W)
|
5000
|
3500
|
Power factor
|
1
|
|
Rated output voltage(Vac)
|
230Vac
|
120Vac
|
Output voltage error
|
±5%
|
|
Output frequency range (Hz)
|
50Hz±0.3Hz/60Hz±0.3Hz
|
|
Maximum Efficiency
|
>92%
|
>91%
|
Overload protection
|
(102%<125%)±10%: report error and turn off the
output after 5 minutes; (125%<150%)±10%: report error and turnoff the output after 10 seconds; Load >150% <125%)±10%: report error and turn off the ±10%: report error and tun off the output after 5 seconds;
|
(102%<110%)±10%: report error and turn off the
output after 5 minutes; (110%<125%)±10%: report error and turn off the output after 10 seconds;(Load >125% <110%)±10%: report error and turn off the ±10%): report error and turn off the output after5 seconds;
|
Peak power
|
10000VA
|
6000VA
|
Loaded motor capability
|
4HP
|
2HP
|
Output short circuit protection
|
Circuit breaker
|
|
Bypass breaker specifications
|
40A
|
|
Rated battery input voltage
|
48V(Minimum starting voltage 44V)
|
|
Battery voltage range
|
Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery…settable on LCD screen)
|
|
Power saving mode
|
Load ≤50W
|
|
AC charging
|
||
Battery type
|
Lead acid or lithium battery
|
|
Maximum charge current
|
60A
|
40A
|
Charge curent error
|
±5Adc
|
|
Charge voltage range
|
40Vdc~58Vdc
|
40Vdc~60Vdc
|
Short circuit protection
|
Circuit breakerand blown fuse
|
|
Circuit breaker specifications
|
40A
|
|
Overcharge protection
|
Alarm and turn off charging after 1 minute
|
|
PV charging
|
||
Maximum PV open circuit voltage
|
145Vdc
|
|
PV operating voltage range
|
60-145Vdc
|
|
MPPT voltage range
|
60-115Vdc
|
|
Battery voltage range
|
40-60Vdc
|
|
Maximum output power
|
4200W
|
|
PV charging current range (can be set)
|
0-80A
|
|
Charging short circuit protection
|
Blown fuse
|
|
Wiring protection
Certified specifications |
Reverse polarity protection
|
|
Certification
|
CE(EN62040-1)
|
|
EMC certification level
|
EN62040-2, C2
|
|
Operating temperature range
|
-15℃ to 55℃
|
|
Storage temperature range
|
-25℃~60℃
|
|
Humidity range
|
5% to 95%(Conformal coating protection)
|
|
Noise
|
≤60dB
|
|
Heat dissipation
|
Forced air cooling, variable speed of fan
|
|
Communication interface
|
USB/RS485(WiFi/GPRS)/Dry node control
|
|
Size(L*W*D)
|
426*322*124mm
|
|
Weight(kg)
|
10.8
|